| Product name | T3Z 068 |
| Standards | IEC 60947-5-1 , IEC 60947-5-5 , ISO 13850 |
| Enclosure material | Grey cast iron, painted |
| Material of the contacts, electrical | Silver |
| Material of the cover | Grey cast iron, painted |
| Length of the wire, maximum | 50 m |
| Gross weight | 4,540 g |
| Product type description | T3Z 068-22yr |
| Article number (order number) | 101087881 |
| EAN (European Article Number) | 4030661057170 |
| [email protected] number, Version 9.0 | 27-37-12-01 |
| Certificates | CE , cULus , cCSAus , EAC |
| Product name | T3Z 068 |
| Standards | IEC 60947-5-1 , IEC 60947-5-5 , ISO 13850 |
| Enclosure material | Grey cast iron, painted |
| Material of the contacts, electrical | Silver |
| Material of the cover | Grey cast iron, painted |
| Length of the wire, maximum | 50 m |
| Gross weight | 4,540 g |
| Reset by pull ring | Yes |
| Number of auxiliary contacts | 2 |
| Number of safety contacts | 2 |
| Standards | ISO 13849-1 |
| Mission Time | 20 Year(s) |
| B10d Normally-closed contact (NC) | 100,000 Operations |
| Actuating element | Roller lever N300 |
| Mechanical life, minimum | 50,000 Operations |
| Positive break angle | 32 ° |
| Actuating force, maximum | 50 N |
| Note (Actuating force) | 30 N in wire direction |
| Actuation direction | Each time 75° right-hand side and left-hand side rotation |
| Positive break force, minimum | 50 N |
| Positive break torque | 0.18 Nm |
| Terminal Connector | Screw connection |
| Cable section, minimum | 0.75 mm² |
| Cable section, maximum | 1.5 mm² |
| Note (Cable section) | All indications about the cable section are including the conductor ferrules. |
| Protection class | IP 65 to IEC/EN 60529 |
| Ambient temperature, minimum | -30 °C |
| Ambient temperature, maximum | +90 °C |
| Rated impulse withstand voltage | 4 kV |
| Thermal test current | 10 A |
| Utilisation category AC-15 | 230 VAC |
| Utilisation category AC-15 | 2.5 A |
| Utilisation category DC-13 | 24 VDC |
| Utilisation category DC-13 | 6 A |
| Switching element | NO contact, NC contact |
| Switching principle | Creep circuit element |
| Note (General) | At 3 m distance intermediate wire supports are required, see accessories |