RSS36-I2-D-R-ST | Safety sensor

RSS36-I2-D-R-ST | Safety sensor

RSS36-I2-D-R-ST | Safety sensor

  • Actuation from side
  • Thermoplastic enclosure
  • 27 mm x 108.2 mm x 35 mm
  • Misaligned actuation possible
  • 1 x connector socket M12, 8-pole
  • Max. 31 sensors can be wired in series.
  • 2 short-circuit proof PNP safety outputs
  • Coding level High according to ISO 14119
  • High repeat accuracy of the switching points
  • Repeated individual coding with RFID technology
  • RFID-technology for needs-based protection against
  • tampering
  • Integral cross-short, wire-breakage and external
  • voltage monitoring of the safety cables up to the
  • control cabinet

General data

Product nameRSS 36
StandardsIEC 60947-5-3
general informationIndividual coding, multiple teaching , High
Active principleRFID
Housing construction formBlock
Installation conditions (mechanical)not flush
Sensor topologySensor for series wiring
Enclosure materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
Active areaGlass-fibre, reinforced thermoplastic
Gross weight100 g
Time to readiness, maximum2,000 ms
Reaction time, maximum100 ms
Duration of risk, maximum200 ms

Special Price A$59.00 was A$437.30
Availability: In stock
Only 4 left
SKU
101214773

Ordering data

Product type descriptionRSS 36-I2-D-R-ST
Article number (order number)101214773
EAN (European Article Number)4030661413396
[email protected] number, Version 9.027-27-24-03

Certifications

CertificatesTÜV , cULus , ECOLAB , EAC , FCC , IC

General data

Product nameRSS 36
StandardsIEC 60947-5-3
general informationIndividual coding, multiple teaching , High
Active principleRFID
Housing construction formBlock
Installation conditions (mechanical)not flush
Sensor topologySensor for series wiring
Enclosure materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
Active areaGlass-fibre, reinforced thermoplastic
Gross weight100 g
Time to readiness, maximum2,000 ms
Reaction time, maximum100 ms
Duration of risk, maximum200 ms

General data - Features

LatchingYes
Diagnostic outputYes
Short circuit detectionYes
Short-circuit recognitionYes
Safety functionsYes
CascadableYes
Integral System Diagnostics, statusYes
Number of LEDs3
Number of semi-conductor outputs with signaling function1
Number of fail-safe digital outputs2

Safety appraisal

StandardsISO 13849-1 , IEC 60947-5-3 , EN 62061 , IEC 61508
Performance Levele
Control category to EN138494
PFH-value2.70 x 10⁻¹⁰ /h
Safety Integrity Level (SIL)3
Mission Time20 Year(s)

Mechanical data

Actuating panelslateral
Active arealateral
MountingA screw length of 25 mm is sufficient for sensor mounting and for side mounting of the actuators. 30 mm long screws are recommended when the actuator is mounted upright and/or when the sealing discs are used.
Switch distance12 mm
Ensured switch distance "ON" Sao10 mm
Ensured switch distance "OFF" Sar20 mm
Hysteresis (Switch distance), maximum2 mm
Repeat accuracy R R0.5 mm
Note (Repeat accuracy R)Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle).Minimum clearance between two sensor systems 100 mm.
Latching force18 N

Mechanical data - Connection technique

Terminal ConnectorConnector M12, 8-pole
NoteThe cable section of the interconnecting cable must be observed! Cable length and cable section alter the voltage drop depending on the output current

Mechanical data - Dimensions

Height of sensor25 mm
Length of sensor22 mm
Width of sensor106.3 mm

Ambient conditions

Protection classIP 65 to IEC/EN 60529 , IP 67 to IEC/EN 60529 , IP 69 to IEC/EN 60529
Ambient temperature, minimum-25 °C
Ambient temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
Storage and transport temperature, maximum+85 °C
Material temperature resistance of the cable (in motion), minimum-10 °C
Material temperature resistance of the cable (at rest), minimum-30 °C
Material temperature resistance (long-term), maximum+105 °C
Resistance to vibrations to EN 60068-2-610 … 55 Hz, amplitude 1 mm
Restistance to shock30 g / 11 ms

Ambient conditions - Insulation value

Rated impulse withstand voltage0.8 kV
Degree of pollution to VDE 01003

Electrical data

Voltage typeDC (direct current)
No-load current100 mA
Rated operating voltage24 VDC −15 % / +10 %
Rated operating voltage minimum20.4 VDC
Rated operating voltage maximum26.4 VDC
Operating current600 mA
Required rated short-circuit current to EN 60947-5-1100 A
Switching frequency approx.1 Hz

Electrical data - Fail-safe digital outputs

Rated operating current (safety outputs)250 mA
Output current (fail-safe output) maximum0.25 A, P-type , 1 V
Current leakage0.5 mA

Electrical data - Diagnostic output, P-type , 2 V


Electrical data - Electromagnetic compatibility (EMC), IEC 61000-6-4 , IEC 60947-3


Status indication

Note (LED switching conditions display)LED yellow: Operating condition , LED green: Supply voltage , LED red: Fault

Pin assignment

PIN 1A1 Ue Brown
PIN 2X1 Safety input 1 White
PIN 3A2 GND Blue
PIN 4Y1 Safety output 1 Black
PIN 5OUT Diagnostic output OUT Grey
PIN 6X2 Safety input 2 violet
PIN 7Y2 Safety output 2 red
PIN 8IN without function Pink

Scope of delivery

Included in deliveryActuators must be ordered separately.

Accessory

Recommendation (actuator)RST 36-1 , RST 36-1-R , PROTECT PSC1 , SRB-E-301ST , SRB-E-201LC

Notes

Note (General)Teaching of the individual coding of a RST actuator through a simple routine during start-up (as -I1). A protected coding process enables teaching a new actuator in case of maintenance.""}]"