AZM400Z-ST2-2P2P-E | Solenoid interlock

AZM400Z-ST2-2P2P-E | Solenoid interlock

AZM400Z-ST2-2P2P-E | Solenoid interlock

  • manual release
  • 2 Diagnostic outputs
  • Clamping force 10.000
  • Guard locking monitored
  • Bistable, motor-driven system
  • 2 Connector M12, 8- and 5-poles
  • High tolerance to door misalignment
  • Universal coding with RFID technology
  • Operation on P/P- and P/N-switching outputs
  • Electric manual release with auxiliary voltage
  • Release possible against lateral forces up to 300
  • N
  • Two-channel input signal of the guard locking
  • function
  • PL e / cat. 4 / SIL 3 for interlocking and guard
  • locking function

General data

Product nameAZM 400
StandardsIEC 60947-5-1 , ISO 13849-1 , IEC 61508 , ISO 14119
general informationUniversal coding , Low
Active principleMagnetic field , RFID
Enclosure materialLight alloy die-casting
Gross weight692 g
Time to readiness, maximum1,500 ms
Reaction time, maximum100 ms

Special Price A$314.00 was A$1,485.20
Availability: In stock
Only 1 left
SKU
103003588

Ordering data

Product type descriptionAZM400Z-ST2-2P2P-E
Article number (order number)103003588
EAN (European Article Number)4030661472638
[email protected] number, Version 9.027-27-26-03

Certifications

CertificatesTÜV , cULus , EAC

General data

Product nameAZM 400
StandardsIEC 60947-5-1 , ISO 13849-1 , IEC 61508 , ISO 14119
general informationUniversal coding , Low
Active principleMagnetic field , RFID
Enclosure materialLight alloy die-casting
Gross weight692 g
Time to readiness, maximum1,500 ms
Reaction time, maximum100 ms

General data - Features

Guard locking monitoredYes
Electronic manual releaseYes
Manual releaseYes
Short circuit detectionYes
Short-circuit recognitionYes
Safety functionsYes
Integral System Diagnostics, statusYes
Number of diagnostic signals2
Number of safety contacts2

Safety appraisal

StandardsISO 13849-1 , IEC 61508

Safety appraisal - Interlocking

Performance Levele
Control category4
PFH-value1.00 x 10-9 /h
PFD value9.00 x 10⁻⁵
Safety Integrity Level (SIL)3
Mission Time20 Year(s)

Safety appraisal - Guard locking

Performance Levele
Control category4
PFH-value1.80 x 10-9 /h
PFD value1.60 x 10⁻⁴
Safety Integrity Level (SIL)3
Mission Time20 Year(s)

Mechanical data

Interlocking principlebistable
Mechanical life, minimum1,000,000 Operations
Note (Mechanical lifetime)Which have a lateral force Ftrans = 100 N: 100.000 operations
Minimum distance devices30 mm
Clamping force in accordance with ISO14119 Fzh10,000 N
Clamping force, maximum Fmax13,000 N
Lateral force at bolt return, maximal (against locked door)300 N
Note (Lateral force at bolt return)Does not apply to emergency exit, Bowden cable and manual release
Tightening torque of the screw8 Nm

Mechanical data - Connection technique

Terminal Connector2 connector M12, 8 and 5 pin

Mechanical data - Dimensions

Height of sensor166.7 mm
Length of sensor46.7 mm
Width of sensor77.8 mm

Ambient conditions

Protection classIP 66 to IEC/EN 60529 , IP 67 to IEC/EN 60529
Ambient temperature, minimum+0 °C
Ambient temperature, maximum+55 °C
Storage and transport temperature, minimum-40 °C
Storage and transport temperature, maximum+85 °C
Resistance to vibrations to EN 60068-2-610 … 150 Hz, amplitude 0.35 mm
Restistance to shock30 g / 11 ms

Ambient conditions - Insulation value

Rated impulse withstand voltage0.8 kV
Degree of pollution to VDE 01003

Electrical data

Operating Current100 mA
Current consumption, maximum600 mA
Current consumption at 24V, minimum10 mA
Current consumption at 24V, maximum15 mA
No-load current100 mA
Rated operating voltage24 VDC
Rated operating voltage24 VDC
Operating current50 mA
Required rated short-circuit current to EN 60947-5-1100 A
Switching frequency approx.0.3 Hz
Open / close cycle (Motor) minimum3
Minimal average cycle time (with continuous operation)20 s

Electrical data - Control inputs

Switching thresholds of the control inputs−3 V … 5 V (Low) , 15 V … 30 V (High)
Allowable discrepancy time (input) maximum10 s, C0 , C1 , C2 , C3

Electrical data - Fail-safe digital inputs, C1


Electrical data - Fail-safe digital outputs

Rated operating current (safety outputs)250 mA, 2 V
Current leakage1.5 mA, C2 , C1 , C2

Electrical data - Diagnostic output

Diagnostic outputshort-circuit proof p-type , 2 V
NoteThe diagnostic output are not safety relevant outputs!

Status indication

Note (LED switching conditions display)Operating condition: LED green , Error / functional defect: LED red , Supply voltage UB: LED green

Pin assignment

ConnectionConnector 1
PIN 1OUT2 Diagnostic output 2
PIN 2E1 Control input 1
PIN 3n.c.
PIN 4Y1 Safety output 1
PIN 5OUT1 Diagnostic output 1
PIN 6E3 Control input 3
PIN 7Y2 Safety output 2
PIN 8E2 Control input 2
ConnectionConnector 2
PIN 1A1 Supply voltage UB
PIN 2H2 GND
PIN 3A2 GND
PIN 4H1 Auxiliary voltage Uhe
PIN 5FE (functional earth connection)

Scope of delivery

Included in deliveryActuators must be ordered separately.
Delivery scope of Mounting material2 x M6 (10.9)

Accessory

Recommendation (actuator)AZM400-B1""}]"