AZM300B-I2-ST-SD2P-T | Solenoid Interlock

AZM300B-I2-ST-SD2P-T | Solenoid Interlock

AZM300B-I2-ST-SD2P-T | Solenoid Interlock

  • Series-wiring
  • Compact design
  • Manual release
  • Emergency exit
  • Power to unlock
  • Actuator monitored
  • Connector M12, 8-pole
  • Thermoplastic enclosure
  • serial diagnostic output
  • 3 different directions of actuation
  • 3 LEDs to show operating conditions
  • Suitable for hinged and sliding guards
  • Suitable for mounting to profile systems
  • Coding level High according to ISO 14119
  • Repeated individual coding with RFID technology
  • RFID-technology for needs-based protection against
  • tampering

General data

Product nameAZM 300
StandardsISO 13849-1 , IEC 61508 , IEC 60947-5-3 , ISO 14119 , IEC 62061
general informationIndividual coding, multiple teaching , High
Active principleRFID
Enclosure materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
Gross weight645.9 g
Time to readiness, maximum5,000 ms
Duration of risk, maximum200 ms

Special Price A$301.00 was A$1,185.00
Availability: In stock
Only 8 left
SKU
103008179

Ordering data

Product type descriptionAZM300B-I2-ST-SD2P-T
Article number (order number)103008179
EAN (European Article Number)4030661452203
[email protected] number, Version 9.027-27-26-03

Certifications

CertificatesTÜV , cULus , ECOLAB , EAC , FCC

General data

Product nameAZM 300
StandardsISO 13849-1 , IEC 61508 , IEC 60947-5-3 , ISO 14119 , IEC 62061
general informationIndividual coding, multiple teaching , High
Active principleRFID
Enclosure materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
Gross weight645.9 g
Time to readiness, maximum5,000 ms
Duration of risk, maximum200 ms

General data - Features

Power to unlockYes
Actuator monitoredYes
Serial diagnosticsYes
LatchingYes
Emergency exitYes
Short circuit detectionYes
Short-circuit recognitionYes
Series-wiringYes
Safety functionsYes
Integral System Diagnostics, statusYes
Number of safety contacts2

Safety appraisal

StandardsISO 13849-1 , IEC 62061 , IEC 61508

Safety appraisal - Interlocking

Performance Levele
Control category4
PFH-value5.20 x 10⁻¹⁰ /h
PFD value4.50 x 10⁻⁵
Safety Integrity Level (SIL)3
Mission Time20 Year(s)

Mechanical data

Mechanical life, minimum1,000,000 Operations
Note (Mechanical lifetime)When using a door hinge > 50,000 operations with door weights ≤ 5 kg;actuating speed ≤ 0.5 m/s
Switch distance2 mm
Ensured switch distance "ON" Sao1 mm
Ensured switch distance "OFF" Sar20 mm
Clamping force in accordance with ISO14119 Fzh1,150 N
Clamping force, maximum Fmax1,500 N
Latching force25 N, 50 N
Tightening torque of the fixing screws, minimum6 Nm
Tightening torque of the fixing screws, maximum7 Nm

Mechanical data - Connection technique

Terminal ConnectorConnector M12, 8-pole, A-coded

Mechanical data - Dimensions

Height of sensor126 mm
Length of sensor35 mm
Width of sensor85 mm

Ambient conditions

Protection classIP66 to IEC 60529 , IP67 to IEC 60529 , IP69 to IEC 60529
Ambient temperature, minimum+0 °C
Ambient temperature, maximum+60 °C
Storage and transport temperature, minimum-10 °C
Storage and transport temperature, maximum+90 °C
Resistance to vibrations to EN 60068-2-610 … 150 Hz, amplitude 0.35 mm
Restistance to shock30 g / 11 ms

Ambient conditions - Insulation value

Rated impulse withstand voltage0.8 kV
Degree of pollution to VDE 01003

Electrical data

Operating voltage, minimum20.4 VDC
Operating voltage, maximum26.4 VDC
No-load current100 mA
Required rated short-circuit current to EN 60947-5-1100 A
Reaction time of actuator, maximum100 ms
Reaction time of input, maximum0.5 ms
Switching frequency, maximum0.5 Hz
NoteCable length and cable section alter the voltage drop depending on the output current

Electrcal data - Solenoid control

Switching thresholds of magnet inputs-3 V … 5 V (Low) , 15 V … 30 V (High) , C0 , C1 , C2 , C3

Electrical data - Fail-safe digital inputs

Switching thresholds of fail-safe inputs−3 V … 5 V (Low) , 15 V … 30 V (High)
Current consumption of the safety inputs at 24V5 mA, C1 , C1 , C2 , C3

Electrical data - Fail-safe digital outputs

Rated operating current (safety outputs)250 mA, 4 V
Current leakage0.5 mA, C2 , C1 , C2

Electrical data - Diagnostic output

Diagnostic outputshort-circuit proof p-type , 4 V

Status indication

Note (LED switching conditions display)Operating condition: LED green , Error / functional defect: LED red , Supply voltage UB: LED green

Pin assignment

PIN 1A1 Supply voltage UB
PIN 2X1 Safety input 1
PIN 3A2 GND
PIN 4Y1 Safety output 1
PIN 5OUT serial diagnostic output
PIN 6X2 Safety input 2
PIN 7Y2 Safety output 2
PIN 8IN serial diagnostic input

Scope of delivery

Included in deliveryActuators must be ordered separately.

Accessory

Recommendation (actuator)AZ/AZM300-B1

Notes

Note (General)For doors that are flush with the door frame the optional mounting plate MP-AZ/AZM300-1 can be used. , For glass and Makrolon doors the optional mounting kit MS-AZ/AZM300-B1-1 can be used. , As long as the actuating unit remains inserted in the solenoid interlock the unlocked safety guard can be relocked. In this case the safety outputs are re-enabled so that the safety guard must not be opened.""}]"

pdf
(Size: 1 MB)